CCJKN - P/N 08600 (BASE PB) SHORT CUT AUTO GLASS ADHESIVE/SEALANT

Product Identification

Product ID:P/N 08600 (BASE PB) SHORT CUT AUTO GLASS ADHESIVE/SEALANT
MSDS Date:01/29/1993
FSC:8040
NIIN:00D020016
Kit Part:Y
MSDS Number: CCJKN

Responsible Party
MINNESOTA MINING AND MFG CO AUTOMOTIVE TRADES DIV
3M CTR
ST PAUL, MN 55144-1000
US

Emergency Phone: 612-773-1110

Info Phone: 612-733-1110

Cage: 52157

Contractor
NAPA, A DIVISION OF LINCOLN AUTOMOTIVE
ST. LOUIS, MO 63120-1578 US

Telephone: 414-255-5520

Cage: 050Q3

Ingredients

POLYOXYPROPYLENE GLYCOL

CAS: 9003-11-6

RTECS: MD0911050

Fraction By Weight: 1-10%


CARBON BLACK

CAS: 1333-86-4

RTECS: FF5800000

Fraction By Weight: 1-10%

OSHA PEL 3.5 MG/M3

ACGIH TLV: 3.5 MG/M3; 9596


PHENYL (C10-C18) ALKYLSULFONATE (PLASTICIZER) OR SULFONIC

CAS: 70775-94-9

Fraction By Weight: 1-10%


TOLUENE (SARA 313) (CERCLA)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 1-10%

OSHA PEL 200 PPM; Z-2

ACGIH TLV: S, 50 PPM; 9596

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


1,4-BUTANEDIOL

CAS: 110-63-4

RTECS: EK0525000

Fraction By Weight: 1-10%


DIMETHYL SILOXANE, REACTION PRODUCT WITH SILICA OR SILICON

CAS: 67762-90-7

Fraction By Weight: 1-10%

OSHA PEL 6 MG/M3

ACGIH TLV: 10 MG/M3


2-ETHYL-2-HYDROXYMETHYL-3-PROPANDIOL

CAS: 77-99-6

RTECS: TY6470000

Fraction By Weight: 1-10%


(GAMMA-MERCAPTOPROPYL) TRIMETHOXYSILANE OR

CAS: 4420-74-0

RTECS: TZ7800000

Fraction By Weight: 1-10%


POLY(TETRAMETHYLENE ETHER) OR

CAS: 25190-06-1

Fraction By Weight: 40-50%


ALPHA-PINENE, PHENOL POLYMER

CAS: 25359-84-6

Fraction By Weight: 10-20%

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EXPOSURE MAY CAUSE EYE, SKIN &
RESPIRATORY TRACT IRRITATION. INGESTION MAY CAUSE GI TRACT
IRRITATION. CHRONIC: NONE SPECIFIED BY MANUFACTURER.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:EYES-IRRITATION, REDNESS, SWELLING, PAIN,
TEARING, HAZY VISION. SKIN-IRRITATION, REDNESS, SWELLING, ITCHING.
INHALED-IRRITATION, SORENESS OF THROAT/NOSE, COUGHING, SNEEZING.
INGESTED-GI TRACT IRRITATI ON, PAIN, VOMITING, ABDOMINAL
TENDERNESS, NAUSEA, BLOOD IN VOMITUS, BLOOD IN FECES.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:IN ALL CASES GET MEDICAL ATTENTION. EYES-FLUSH WITH WATER FOR
15 MINUTES. SKIN-FLUSH WITH LOTS OF WATER. INHALED-REMOVE TO FRESH
AIR. INGESTED-DO NOT INDUCE VOMITING! IF CONSCIOUS, DRINK 2 GLASSES
WAT ER. CALL A PHYSICIAN.

Fire Fighting

Flash Point Method:TCC
Flash Point:155F,68C
Lower Limits:1.30
Upper Limits:7.00
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
FULL FIRE FIGHTER'S PROTECTIVE GEAR.
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS EXPOSED TO HEAT FROM
FIRE MAY BUILD PRESSURE AND EXPLODE.

Accidental Release

Spill Release Procedures:REFER TO OTHER MSDS SECTIONS FOR ADVICE ON
PHYSICAL & HEALTH HAZARDS, RESPIRATORY PROTECTION, VENTILATION, &
PERSONAL PROTECTIVE EQUIPMENT. CALL 612-733-1110/733-6100 FOR 24-HR
SPILL ASSISTANCE. COLLE CT SPILLED MATERIAL, PLACE IN CONTAINER&
SEAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:COMBUSTIBLE! KEEP CONTAINER TIGHTLY
CLOSED. KEEP OUT OF REACH OF CHILDREN. USE IN A WELL-VENTILATED
AREA. AVOID SKIN CONTACT. AVOID EYE CONTACT.
Other Precautions:DO NOT INGEST. AVOID PROLONGED BREATHING OF PRODUCT.
WHEN THIS BASE IS USED IN COMBINATION WITH THE ACCELERATOR FOLLOW
THE PRECAUTIONS OUTLINED IN THE ACCELERATOR MATERIAL DATA SHEET.

Exposure Controls

Respiratory Protection:IF ENGINEERING CONTROLS FAIL OR NON-ROUTINE USE
OR AN EMERGENCY OCCURS; WEAR AN MSHA/NIOSH APPROVED AIR-SUPPLIED
RESPIRATOR OR SCBA, AS REQUIRED. USE IAW 29 CFR 1910.134.
Ventilation:USE IN A WELL-VENTILATED AREA. USE ADEQUATE MECHANICAL
VENTILATION OR LOCAL EXHAUST TO MAINTAIN EXPOSURE BELOW TLV(S).
Protective Gloves:IMPERVIOUS-PVA, TEFLON, VITON.
Eye Protection:SAFETY GLASSES/CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER. DLA-HMIS:
EYE WASH STATION & SAFETY SHOWER.
Work Hygienic Practices:WASH HANDS AFTER HANDLING AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health
KEY1=F8. THIS BASE (PB-5190) USED WITH 3M SHORT-CUT AUTO GLASS
ADHESIVE/SEALANT P/N 08600 (ACCELERATOR-PB); MFG #PB-5025, MSDS DOC
#1114073).

Chemical Properties

HCC:V4
Boiling Pt:B.P. Text:232F,111C
Vapor Pres:25.19
Vapor Density:3.14
Spec Gravity:1.010
Viscosity:PASTE
Evaporation Rate & Reference:4.50 (ETHER=1)
Solubility in Water:SLIGHT
Appearance and Odor:THIXOPTROPIC PASTE; SWEET ODOR (COMBINED WITH
ACCELERATOR-PUNGENT ODOR).
Percent Volatiles by Volume:6

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE AND CARBON DIOXIDE,
TOXIC VAPORS, GASES OR PARTICULATES.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL ENVIRONMENTAL REGULATIONS. EPA/RCRA HAZWASTE NUMBER-NONE.
CURE PRODUCT ACCORDING TO INSTRUCTIONS. INCINERATE IN AN INDUSTRIAL
OR COMMERCIAL FACIL ITY IN PRESENCE OF COMBUSTIBLE MATERIAL.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.